We research and compare products using published specifications, features and owner feedback. When you buy through our links, we may earn a commission. As an Amazon Associate I earn from qualifying purchases. Learn more›

ARB Air Locker Compressor Wiring Diagram: Step-by-Step Guide

Follow this arb air locker compressor wiring diagram guide to connect power, ground, relay and switch correctly, with fuse sizing and common wiring mistakes cov

Updated November 2026

An arb air locker compressor wiring diagram shows how power travels from the battery, through a fuse and relay, to the compressor motor, with a separate control circuit running to the dash switch. Once you understand that layout, you can wire the compressor so it runs only when you want it to, is protected from overcurrent, and does not drain the starting battery. This guide walks through the circuit in the order you would build it.

Understand the Circuit Layout Before You Connect Anything

The compressor circuit has two halves. The high-current side carries power from the battery positive terminal through an inline fuse and a heavy-duty relay to the compressor motor, with the motor grounded to the chassis or battery negative. The low-current control side runs from a fused ignition or accessory source through the dash switch to the relay coil, so the relay only closes when you press the switch. Keeping these two halves separate is what makes the system safe and easy to troubleshoot.

Shopping for one? See our guide: ARB Air Locker Differential Review (2026).

Wire the High-Current Power Path

Run a heavy gauge wire from the positive battery terminal to the compressor, routing it away from moving suspension parts, exhaust heat and sharp edges. Install an inline fuse as close to the battery as practical, and size it to the compressor’s rated current draw as listed in the manufacturer’s manual. Terminate the motor ground with a short, heavy cable bolted to clean bare metal, because a poor ground is the most common cause of weak operation.

Key Points for the High-Current Side

  • Use wire gauge matched to the run length and the compressor’s amp draw, not the gauge of the control wire.
  • Place the fuse within a few inches of the battery positive post.
  • Fit the relay in the power path so the switch never carries motor current.

Wire the Control Circuit and Dash Switch

Take a fused feed from a switched accessory source and route it to one side of the dash switch. Run the other side of the switch to the relay coil, and connect the coil’s opposite terminal to ground. Most relays use a numbered terminal layout printed on the housing, so confirm pin 30 (battery feed), pin 87 (output to compressor), pin 85 and pin 86 (coil) before crimping anything. Keep control wiring at a smaller gauge, but do not run it alongside the high-current cable for long distances, since induced noise can cause erratic switching.

Verify Before You Close Everything Up

Before securing trim panels, test each connection with a multimeter. Check for battery voltage at the fuse input and at the relay pin 30. With the switch on, confirm the relay coil receives voltage and that pin 87 gets power when the relay clicks. Then run the compressor briefly and check that it builds pressure and shuts off at its cutout. Heat up of the cables, a slow motor, or a blown fuse at this stage points to undersized wire or a loose ground.

Common Mistakes

  • Powering the compressor directly through the dash switch, which overheats the switch and wears it out quickly.
  • Using a ground through painted or greasy brackets instead of bare metal.
  • Sizing the fuse by guesswork rather than by the compressor’s stated current draw.
  • Routing control wires where they can chafe against the frame or moving parts.
  • Skipping a relay and assuming the switch can handle the load.
  • A digital multimeter lets you confirm voltage at each relay pin and check ground continuity before powering the compressor. View on Amazon
  • A crimp tool and heat-shrink terminal kit makes solid, weatherproof connections on the power and ground runs. View on Amazon
  • A automotive relay with a fused harness makes a clean, labeled installation for the compressor circuit. View on Amazon

For related setup and fault-finding, see ARB Air Locker Compressor: Setup, Sizing and Troubleshooting Guide and ARB Air Locker Compressor Keeps Running: Causes and Fixes. If the switch itself is failing, ARB Air Locker Switch Panel: Wiring, Setup and Troubleshooting Steps covers that component in detail.

FAQ

What size fuse should I use for an air locker compressor?

Size the fuse to the compressor’s rated current draw as listed in the manufacturer’s manual, adding the margin the fuse rating allows. Never use a fuse larger than the wire gauge can safely carry.

Can I power the compressor directly from the dash switch?

It is not recommended. The switch should only energize a relay coil, which then carries the motor current, so the switch does not overheat or wear out.

Why does my compressor run slowly after wiring it up?

The most common causes are a poor ground, undersized power wire, or a corroded connection causing voltage drop. Measure voltage at the motor while it runs; a large drop points to the wiring rather than the compressor. Consult a qualified automotive electrician if you are unsure.

Conclusion

A correct arb air locker compressor wiring diagram separates the high-current power path from the low-current switch circuit, protected by a properly sized fuse and relay. Build the power side first, wire the control side second, and verify each connection with a multimeter before finishing the install. Taking these steps in order makes the system reliable on the trail and much easier to troubleshoot later.

Graham Fisher

About Graham Fisher

Graham Fisher is part of our editorial team and reviews and edits our off-road vehicle upgrades guides, checking product details against manufacturer specifications and owner feedback.

About the author

Graham Fisher
Graham Fisher

Graham Fisher writes reviews and buying guides for Offroad Lockers.